| Model ASHG07KGTE/AOHG07KGCA | | Cooling | Heating |
|---|
| Power | kW | 2.0 (0.9-3.2) | 2.5 (0.9-5.2) |
| Consumption | kW | 0.400 | 0.500 |
| Seasonal energy efficiency ratio SEER | W/W | 8.10 A++ | - |
| Seasonal coefficient of performance SCOP | W/W | - | 5.30 A+++ |
| Annual consumption | kWh/a | 86 | 606 |
| Permissible outdoor temperature limits | °C DB | -10 to 46 | -15 to 24 |
| | | |
| Unit | | Indoor | Outdoor |
| Air circulation | m³/h | 650 | 1610 |
| Dimensions (Height/ Length/ Width) | mm | 270×834×215 | 542×799×290 |
| Weight | kg | 10 | 30 |
| Noise level (Q) | dB(A) | 38/33/29/21 | 46 |
| Drain pipe diameter | mm | 13.8/15.8 to 16.7 | |
| | | |
| Technical data | | | |
| Frequency / Phase / | V/Ø/Hz | 230/1/50 | |
| Dry | I/h | 1.0 | |
| Pipe diameter (liquid/gas) | mm | 6.35/9.52 | |
| Maximum pipe length | m | 20 | |
| Height difference | m | 15 | |
| Refrigerant | | R32 | |
![]()
saving via occupancy sensor The occupancy sensor detects the movement of people in the room and decides when to switch on the energy-saving mode.
![]()
Economy mode The thermostat settings change automatically depending on the temperature, to avoid unnecessary cooling or heating.
![]()
Room temperature set point limit (option) The minimum and maximum temperature range can be set to provide additional energy savings while taking occupant comfort into account.
![]()
Automatic return to set temperature (option) The set temperature automatically returns to the previously set temperature.
![]()
Powerful heating The heating capacity remains high even at very low outdoor temperatures of -7°C.
![]()
Powerful mode Operation at maximum airflow and compressor speed allows comfort in the room to be reached quickly.
![]()
10°C heating The room temperature can be maintained at no more than 10°C, so the room will not get cold when not in use.
![]()
Quiet operating mode Noise levels of the outdoor unit can be selected.
![]()
Automatic mode changeover The air conditioning systems automatically switch operating modes (between heating and cooling) depending on the set temperature and the room temperature.
![]()
Up/down louver setting The louvers can move up and down automatically.
![]()
Automatic fan speed A microcomputer automatically adjusts the airflow to efficiently follow changes in the room temperature.
![]()
Auto restart In the event of a temporary power failure, the air conditioner will automatically restart in the previous mode once power is restored.
![]()
Auto-off timer (option) Automatically stops operation once the time fixed after start-up has elapsed.
![]()
Sleep timer The microcomputer gradually changes the room temperature automatically to ensure a comfortable night's sleep.
![]()
Program timer This digital timer allows one of four options to be selected: ON, OFF, ON » OFF or OFF « ON
![]()
Weekly timer Different on/off times can be set for each day.
![]()
Weekly timer + setback (option) Temperatures can be set for two time periods and for each day of the week.
![]()
Filter indicator A lamp shows when the filter needs cleaning.
![]()
External error output (option)
![]()
External on/ off input (option)
![]()
Wireless LAN control (option) The additional Wi-Fi adapter lets you control the air conditioner via smartphone, tablet or from outside.
![]()
Ion deodorising filter The filter works by effectively neutralising accumulated odours and activating the oxidising and decomposing effects of the ions generated by the ultra-fine particle ceramic.
![]()
Apple-catechin filter The apple-catechin filter uses static electricity to clean fine particles and dust from the air.
![]()
Washable panel As the front panel is easy to remove, maintenance is also easy.
![]()
All DC models Highly efficient DC inverter processor, allowing higher energy efficiency compared with conventional compressors.
![]()
Refrigerant R32 New eco-friendly refrigerant with a global warming potential 1/3 lower than R410A.