Technical specifications:
Outdoor t˚/ water circuit t˚ - OT = 7˚C, WC = 65˚C
Heating capacity - 11.30 kW
Power consumption nom. - 3.80 kW
COP - 2.97
Outdoor unit dimensions in mm (H x W x D) - 1345 x 900 x 320 mm
Outdoor unit weight - 120 kg.
Indoor hydrobox dimensions in mm (H x W x D) - 705 x 600 x 695 mm
Indoor hydrobox weight - 144 kg.
Power supply Hz/V/A - V1/1∼/50 Hz/220-240V 25A
Water circuit t˚/ heating - 25˚C to 80˚C
Water circuit t˚/ DHW - 25˚C to 80˚C
Outdoor application t˚ - heating -20˚ to + 20˚C / DHW -20˚ to + 35˚C
Liquid/gas pipes - Ø16 mm / Ø10 mm
-
Manufacturer:Daikin Altherma
-
Refrigerant:R410A
-
Power supply:Single phase